When installing sanitary and stormwater systems, one of the most important considerations is the minimum cover (depth of soil above a pipe). Cover is critical for protecting buried pipes from external loads such as foot traffic, vehicles, or construction equipment. If pipes are laid too shallow, they can crack, deform, or become exposed over time.
This article explains the typical minimum cover requirements, why they exist, and what to consider when pipes must be laid at shallow depths.
What Is Minimum Pipe Cover?
Minimum pipe cover refers to the vertical distance between the finished ground surface and the crown (top) of the pipe. This depth ensures that the surrounding soil can:
Absorb and distribute surface loads.
Protect pipes from accidental damage.
Maintain structural integrity of the installation.
Typical Minimum Cover Requirements
Standards vary slightly by material and jurisdiction, but common guidelines are:
Non-trafficable areas (e.g., gardens, lawns):
PVC stormwater/sewer pipes: 300 mm minimum cover.
Concrete pipes: 150–300 mm depending on class.
Trafficable areas (e.g., driveways, car parks):
PVC pipes: 450–600 mm minimum cover.
Concrete/ductile iron pipes: Can be reduced to 300 mm due to higher strength.
Road crossings or heavy vehicle areas:
Minimum cover of 600–750 mm is usually required, or protection slabs may be specified.

Extract from AS3500 typical requirement for cover over storm and sanitary pipes
Factors That Influence Minimum Cover
Pipe Material and Class – Stronger pipes like concrete or ductile iron require less cover than flexible pipes such as PVC.
Traffic Loads – Areas subject to car or truck traffic need greater protection than landscaped areas.
Soil Conditions – Weak or loose soils may require increased cover for stability.
Construction Risk – Shallow pipes are more vulnerable to disturbance during future works.
What If Minimum Cover Cannot Be Achieved?
In some cases, site constraints mean pipes must be laid shallower than standard requirements. Options include:
Concrete encasement – surrounding the pipe in concrete to provide additional protection.
Protective slabs – reinforced slabs above the pipe to spread loads.
Upgrading pipe class – using higher strength pipes designed for shallow cover.
These solutions are often required for services passing through driveways, beneath retaining walls, or where excavation depth is limited.
Compliance and Standards
In Australia, minimum pipe cover requirements are set out in:
AS/NZS 3500.2 – Sanitary plumbing and drainage
AS/NZS 3500.3 – Stormwater drainage
AS/NZS 3725 – Concrete pipe installation
Local councils and utility providers may also impose specific requirements depending on land use and traffic conditions, so always double check with the local council as to these requirements.